Panasonic Earth leakage or short circuit in heating circuit

Oven trips the household circuit breaker or RCD when heating is started.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Heater element shorted to chassis, Damaged wiring insulation touching metal, Moisture ingress in elements or connectors, Faulty power board causing short

How to Fix / Troubleshooting

Danger: This involves live mains and potential earth faults. If you are not experienced, contact a qualified electrician or technician.

  • 1. Identify when it trips: Note whether the breaker trips immediately when the oven is turned on, or only when a specific mode (e.g., grill) is selected.
  • 2. Isolate elements: With power off, disconnect one element at a time and test the oven. If the breaker no longer trips when a particular element is disconnected, that element is likely shorted.
  • 3. Insulation test (advanced): Use a megohmmeter to test insulation resistance between each element terminal and chassis. Low resistance indicates leakage.
  • 4. Inspect wiring: Check for melted or pinched wires where they pass through metal panels or near hot areas.
  • 5. Dry out moisture: If the oven was recently steam-cleaned or exposed to moisture, allow it to dry thoroughly (door open, power off) for 24 hours and retest.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Grill / Upper Heater Element
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements