F09
Proline Touch Control Panel / Keypad Error

Oven beeps and shows F09, some buttons may not respond or respond erratically

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty touch control membrane, Moisture ingress behind control panel, Loose ribbon cable between keypad and PCB, Failed user interface PCB

How to Fix / Troubleshooting

Safety first: Switch off power at the breaker before removing any panels.

  • Dry out moisture: If F09 appeared after heavy steam use or cleaning, leave the oven powered off for several hours with the door open to allow moisture to evaporate.
  • Access control fascia: Remove the front control panel screws and gently pull the fascia forward to expose the keypad ribbon cable and user interface PCB.
  • Check ribbon cable: Ensure the flat cable is fully inserted and not damaged. Reseat it carefully.
  • Inspect for corrosion: Look for signs of moisture or corrosion on the keypad contacts and PCB. Lightly clean with isopropyl alcohol if minor.
  • Keypad test: If certain keys never respond, the membrane keypad is likely faulty and the entire control fascia or keypad assembly must be replaced.
  • UI PCB replacement: If all keys are affected and reseating cables does not help, replace the user interface PCB.