F15
Proline
Cooling Fan Control Fault
Cooling fan runs continuously even when oven is off, or F15 error appears after cooking
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck cooling fan relay on PCB, Shorted temperature sensor near control area, Faulty cooling fan thermostat, Wiring short keeping fan energized
How to Fix / Troubleshooting
Safety first: Disconnect mains power before working on the oven.
- Allow cool-down: Confirm that the oven is completely cool. Some models keep the fan running until a safe temperature is reached; this is normal. If it runs for hours, there is a fault.
- Check cooling thermostat: Locate the cooling fan thermostat (often on the top of the cavity). Test for continuity at room temperature. If it remains closed when cool, replace it.
- Inspect control PCB: Look for a stuck relay controlling the fan. If the relay contacts are welded closed, the PCB must be replaced.
- Wiring check: Ensure no wires are shorted together at the fan or thermostat terminals.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Cooling Fan Thermostat
Check Price on Amazon