F15
Proline Cooling Fan Control Fault

Cooling fan runs continuously even when oven is off, or F15 error appears after cooking

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck cooling fan relay on PCB, Shorted temperature sensor near control area, Faulty cooling fan thermostat, Wiring short keeping fan energized

How to Fix / Troubleshooting

Safety first: Disconnect mains power before working on the oven.

  • Allow cool-down: Confirm that the oven is completely cool. Some models keep the fan running until a safe temperature is reached; this is normal. If it runs for hours, there is a fault.
  • Check cooling thermostat: Locate the cooling fan thermostat (often on the top of the cavity). Test for continuity at room temperature. If it remains closed when cool, replace it.
  • Inspect control PCB: Look for a stuck relay controlling the fan. If the relay contacts are welded closed, the PCB must be replaced.
  • Wiring check: Ensure no wires are shorted together at the fan or thermostat terminals.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Cooling Fan Thermostat
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements