F20
Proline Mode / Temperature Configuration Error

Oven beeps and shows F20 when attempting to start, fan may run briefly then stop

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Invalid configuration data in control PCB, Incorrect replacement PCB not programmed for model, Corrupted EEPROM settings

How to Fix / Troubleshooting

Safety first: Turn off power before removing panels.

  • Power reset: Disconnect power for at least 5 minutes to allow the control to fully reset. Restore power and attempt to set the clock and a basic cooking mode.
  • Check model configuration: If a control board was recently replaced, verify that the correct Proline part number was installed and that any required configuration procedure (jumper settings or programming) was completed according to the service manual.
  • Service mode (if available): Some models allow a configuration reset via a key sequence. Refer to Proline technical documentation.
  • Replace PCB: If configuration cannot be corrected and F20 persists, replace the main control PCB with the correct, pre-configured part.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements