F12
RCA Communication Error Between Display and Control

RCA oven displays F12 and may not operate; display may be blank or show partial characters.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose harness between display module and main control, Failed display board, Failed main control board, Power supply issue to control electronics

How to Fix / Troubleshooting

Safety first: Disconnect power at the breaker before accessing internal controls.

  • Power reset: Turn the breaker OFF for 5 minutes, then ON. If F12 returns immediately, proceed with inspection.
  • Inspect harness connections: Remove the control panel back cover. Locate the wiring harness between the display module and the main EOC. Unplug and firmly reconnect all related connectors.
  • Check for corrosion or burns: Look for discoloration, corrosion, or melted plastic at connectors. Replace any damaged harnesses.
  • Board diagnosis: If wiring is intact, either the display board or the electronic oven control board is faulty. Many RCA ovens integrate these; in that case, replace the combined control module.
  • Verify correct voltage: With power ON (only if you are qualified), verify that the control is receiving proper line voltage per the wiring diagram. Incorrect supply can cause F12.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Electronic Oven Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements