E18
Russell Hobbs Stuck Relay / Output Driver Fault

Oven shows E18 and the fan or light may turn on unexpectedly or not at all.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Relay contacts welded closed or open, Failed triac driving fan or light, PCB track damage around relay, Overheating of control board

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker before opening the control panel.

  • Observe behaviour: Note which function (fan, light, element) is stuck on or off when E18 appears.
  • Inspect PCB: Remove the control board and locate the relay or triac associated with the affected function. Look for discoloration, cracking, or melted solder.
  • Tap test (temporary check): With power disconnected, gently tap the relay body. If the problem temporarily changes after re-powering, the relay is likely sticking and should be replaced.
  • Replace PCB or relay: For most users, replacing the entire main control PCB is safer than desoldering individual relays.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements