F6
Sharp Communication error between display and power board

Sharp oven shows F6 and may not respond to keypad inputs or may behave erratically.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose harness between display PCB and power/control PCB, oxidized connectors, failed display board, failed main control board

How to Fix / Troubleshooting

Safety: Disconnect power before accessing internal electronics.

  • Access control area: Remove the top or front trim to expose the display PCB and main control board.
  • Check harness connections: Locate the multi-pin connectors between the display and main board. Unplug and firmly replug them several times to clean contacts.
  • Inspect for damage: Look for signs of moisture, corrosion, or burnt components on either board. If present, the affected board should be replaced.
  • Isolate faulty board: If available, consult the service manual for voltage or signal checks between boards. In many cases, technicians substitute a known-good display or main board to identify the failed part.
  • Replace defective PCB: Replace the display PCB if the display is dim/garbled and F6 appears. Replace the main control board if power relays and logic are affected.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Display PCB
Check Price on Amazon

We may earn a commission from links on this page.