E006
Siemens Control Panel / User Interface Communication Error

Oven does not start, E006 appears immediately when a program is selected

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose ribbon cable between touch control and main PCB, Failed touch control module, Corroded connector on control board

How to Fix / Troubleshooting

Safety: Isolate the oven from mains before removing the control panel.

  • Power cycle: Turn off power for 10 minutes to clear any temporary communication error. If E006 persists, proceed.
  • Remove control panel: Open the oven door, remove the screws securing the fascia, and gently pull the control panel forward.
  • Check ribbon cables: Locate the flat ribbon cable(s) between the display/touch board and the main control module. Reseat them carefully, ensuring they are fully inserted and not kinked.
  • Inspect for damage: Look for signs of moisture ingress, corrosion, or burnt components on the user interface board.
  • Test operation: Reassemble temporarily, restore power, and test. If E006 remains, the user interface or main board may need replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Control Panel / User Interface PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements