F21
Signature Kitchen Suite
Broil ignition failure
Gas broil burner will not ignite; F21 displayed on gas models
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed broil igniter, Faulty broil gas valve, Blocked broil burner ports, Loose igniter wiring
How to Fix / Troubleshooting
Safety first: Turn off gas and power before servicing. If you detect a strong gas odor, leave the area and contact your gas provider.
- Step 1 – Check broil operation: Start a broil cycle and observe the broil igniter through the oven door. If it does not glow or the burner does not light, proceed.
- Step 2 – Access broil igniter: Turn off power and gas. Remove the oven racks and broil shield to access the broil burner and igniter.
- Step 3 – Inspect igniter and burner: Look for cracks in the igniter and heavy debris blocking the burner ports. Clean the burner with a soft brush if clogged.
- Step 4 – Test igniter: Disconnect the igniter and measure resistance. Replace if open or significantly out of specification.
- Step 5 – Wiring and valve: Check igniter wiring for secure connections. If a new igniter glows but the burner does not light, the broil gas valve or control board may be faulty and should be diagnosed by a technician.
Note: Use only OEM igniters; generic parts may not draw the correct current to open the gas valve.