F22
Signature Kitchen Suite Cooling fan circuit fault

Cooling fan runs continuously or not at all; F22 displayed

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed cooling fan motor, Stuck cooling fan relay, Blocked cooling air passages, Faulty temperature sensor near control

How to Fix / Troubleshooting

Safety first: Disconnect power at the breaker before accessing internal fans.

  • Step 1 – Observe fan behavior: After using the oven, the cooling fan should run for a short time then shut off. If it never runs or runs constantly, F22 may appear.
  • Step 2 – Access cooling fan: Remove the upper rear panel to locate the cooling fan assembly behind the control panel area.
  • Step 3 – Inspect fan: Check for obstructions, dust buildup, or signs of overheating. Spin the fan blade by hand; it should move freely.
  • Step 4 – Test motor: Disconnect the fan and measure resistance across the motor terminals. An open circuit indicates a failed motor.
  • Step 5 – Control relay: If the motor is good but never receives power, or receives constant power, the control board's fan relay may be stuck and the board will need replacement.

Warning: Do not operate the oven with a non-functioning cooling fan; this can overheat the electronics and cause further damage.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Cooling Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements