Er18
SMEG Temperature Calibration / Sensor Range Error

Smeg oven shows Er18 and the interior temperature seems incorrect compared to the set value.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Drifted NTC temperature sensor, poor sensor contact with cavity, incorrect calibration data in control board, wiring resistance affecting reading

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing the sensor or control board.

  • Verify with thermometer: Use an accurate oven thermometer to compare actual cavity temperature with the set temperature at several points (e.g., 150°C, 180°C, 200°C).
  • Inspect sensor mounting: Ensure the NTC sensor is firmly mounted and not loose or pulled away from the cavity wall.
  • Test sensor resistance: Remove and measure the sensor at room temperature and, if possible, at a known elevated temperature (e.g., in warm water). Compare with Smeg specifications. Replace if out of tolerance.
  • Calibration: Some Smeg models allow temperature offset adjustment via the user menu or service mode. Apply a small offset if readings are consistently off but sensor is good.
  • Control board replacement: If calibration cannot correct the error and the sensor and wiring are good, replace the main control board.