F06
Viking
Broil Element or Broil Relay Fault
Viking oven shows F06; broil function will not operate or shuts off quickly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open broil element, Loose or burned broil element terminals, Failed broil relay on EOC, High-limit thermostat open in broil circuit
How to Fix / Troubleshooting
Safety: Turn off power at the breaker. Heating elements can retain heat; allow to cool.
Check the broil element:
- Visually inspect the broil element at the top of the oven cavity for blisters, breaks, or burn marks.
- Remove the mounting screws and gently pull the element forward to access the terminals.
- Disconnect the wires and measure resistance across the element. A typical broil element should read between 10–40 Ω. If open (infinite resistance), replace the broil element.
- Inspect the terminal ends and wiring for heat damage; repair or replace as needed.
- If the element tests good, check continuity through any high-limit thermostat in the broil circuit (often mounted on the rear or top of the oven). Replace if open.
- If all components test good, the broil relay on the EOC may be faulty; replace the control board.