Viking Mechanical Vibration / Loose Components

Viking oven makes loud banging or rattling noises during convection or when heating.

Advertisements

Possible Causes

Loose convection fan blade or mounting screws, Warped or loose oven racks, Loose internal panels or heat shields, Failing convection motor bearings

How to Fix / Troubleshooting

Safety: Turn off power and allow the oven to cool before tightening or removing parts.

Steps:

  • Remove all racks and accessories, then run the oven briefly to see if the noise disappears. If so, inspect racks for warping and ensure they are seated properly.
  • Remove the convection fan cover and check that the fan blade is tight on the shaft and not contacting the cover. Tighten or replace as needed.
  • Inspect internal panels and heat shields for loose screws; tighten all accessible fasteners.
  • If the noise is a grinding or squealing from the fan area, the convection motor bearings may be failing; replace the motor assembly.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Convection Fan Motor Assembly
Check Price on Amazon