FAN
Broil King Crown Pellet Combustion Fan Speed or Feedback Fault

Display shows FAN or fan warning; grill runs but temperature is unstable or smoke is minimal.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty or obstructed combustion fan, Failing fan motor, Loose fan wiring, Faulty fan speed feedback circuit on control board

How to Fix / Troubleshooting

Safety first: Disconnect power and wait for the grill to cool.

  • Clean the fan: Access the combustion fan and clean blades and housing with a brush or compressed air. Remove ash and grease that may slow the fan.
  • Check for obstructions: Ensure no wires, foil, or debris are contacting the fan blades.
  • Verify wiring: Confirm the fan connector is secure at the control board and at the fan motor.
  • Test operation: Reconnect power and start the grill. Listen for steady fan operation. If the fan is noisy, slow, or intermittent, replace the combustion fan assembly.
  • Controller diagnosis: If a new fan does not resolve the FAN error, the control board’s fan circuit may be defective and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Combustion Fan
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements