Camp Chef
Intermittent Flame-Out Without Code
Grill starts but shuts down mid-cook without any error code; fire goes out and temperature drops.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Pellet bridging in hopper, Weak auger motor, Excessive ash in firepot, Intermittent combustion fan operation
How to Fix / Troubleshooting
Safety first: Turn OFF and unplug the grill. Allow it to cool before cleaning.
- Clean firepot thoroughly: Remove all ash and debris to ensure consistent combustion.
- Stir pellets: During long cooks, occasionally check and stir pellets to prevent bridging.
- Observe auger and fan: Run the grill with grates removed and watch that pellets feed and the fan runs continuously. If either stops intermittently, inspect wiring and replace the failing component.
- Use quality pellets: Switch to a reputable brand of hardwood pellets with low dust content.
Advertisements
Repair Difficulty
Medium
3/5