Temp Err
Green Mountain Grills Temperature Sensing / Control Error

Display shows 'Temp Err' or temperature error and grill behaves unpredictably.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

RTD probe reading out of range, Loose RTD connector, Control board ADC failure, RTD wire damaged by heat

How to Fix / Troubleshooting

Safety first: Unplug the grill before accessing the controller or RTD wiring.

  • Inspect RTD probe: Check that the probe is clean, not coated in heavy grease, and not bent or touching metal surfaces.
  • Check wiring: Ensure the RTD cable is intact and not melted where it passes through the grill wall.
  • Reconnect RTD: Unplug and firmly replug the RTD connector on the control board.
  • Compare temperatures: Use an external grill thermometer to compare readings. If the GMG display is far off, replace the RTD probe.
  • Replace control board: If a new RTD does not resolve the error, the temperature input circuit on the board may be faulty and the board should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

RTD Temperature Probe
Check Price on Amazon