Memphis Grills Temperature Overshoot / Poor PID Tuning Response

Grill overshoots set temperature by 50°F or more and cycles widely

Advertisements

Possible Causes

Grease or soot on RTD sensor, RTD sensor not fully seated, Controller PID parameters out of calibration, Excessive pellet feed rate

How to Fix / Troubleshooting

Safety: Allow the grill to cool before touching the internal sensor.

  • Clean RTD sensor: Gently wipe the internal temperature probe with a soft cloth to remove grease and soot. Do not use abrasive pads.
  • Check mounting: Ensure the RTD probe is firmly mounted and not loose or touching metal surfaces that could cause lagging readings.
  • Firmware update: Check Memphis documentation for any controller firmware updates that improve temperature control and apply as directed.
  • Pellet feed check: Verify that the auger is not running excessively at low setpoints. If it is, the controller may be faulty and require replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

RTD Temperature Probe
Check Price on Amazon