Memphis Grills
Intermittent Pellet Feed
Pellets not feeding consistently, temperature swings low then recovers
Advertisements
Possible Causes
Pellet bridging in hopper, Excess dust in pellets, Auger motor overheating and cycling off, Loose auger wiring
How to Fix / Troubleshooting
Safety: Unplug the grill before working in the hopper or on wiring.
- Stir pellets: During cooks, occasionally stir pellets to prevent bridging, especially when hopper is low.
- Clean hopper: Empty and vacuum the hopper to remove dust and fines.
- Inspect auger motor: Check for signs of overheating or discoloration. Ensure the motor has adequate ventilation.
- Check wiring: Reseat auger motor connectors at the controller and motor. Repair any loose or damaged wires.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements