FAN
Monument Grills
Combustion Fan Feedback Error
Display shows FAN or FAN ERR and grill will not continue the cook cycle
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Combustion fan not spinning, Fan blades obstructed by debris, Loose fan connector at control board, Failed fan motor winding
How to Fix / Troubleshooting
Safety first: Unplug the grill and ensure all components are cool before accessing the fan.
- Step 1 – Access fan: Remove the lower or rear access panel to expose the Monument combustion fan assembly.
- Step 2 – Check for obstructions: Spin the fan blades by hand. Remove any debris, insulation, or wiring that may be contacting the blades.
- Step 3 – Inspect wiring: Verify that the fan connector is firmly plugged into the main control board and that wires are not damaged.
- Step 4 – Test fan during startup: Reassemble enough to safely run the grill. Plug in, start a cycle, and observe whether the fan starts. If it does not, stop the cycle and unplug.
- Step 5 – Replace fan: If the fan does not run and tests open on a multimeter, replace the combustion fan motor with an OEM Monument unit.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Combustion Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.