Monument Grills Grease Management System Overflow or Misrouting

Grease leaking from front or sides of grill cabinet

Advertisements

Possible Causes

Clogged grease channel or drain hole, Misaligned drip tray, Overfilled grease bucket, Grill not level front‑to‑back

How to Fix / Troubleshooting

Safety first: Ensure the grill is cool before handling greasy components. Grease can be flammable.

  • Step 1 – Level the grill: Use a level to ensure the Monument grill tilts slightly toward the grease drain side. Adjust casters or legs as needed.
  • Step 2 – Clean grease channel: Remove grates and drip tray. Scrape and wipe the grease channel and drain opening. Use a small brush or pipe cleaner to clear the drain.
  • Step 3 – Check drip tray alignment: Reinstall the drip tray so that it fully covers the firepot area and directs grease toward the drain.
  • Step 4 – Empty grease bucket: Regularly empty and clean the external grease bucket or cup.
  • Step 5 – Inspect for damage: If leaks persist, inspect the drip tray and drain tube for cracks or warping and replace if necessary.
Advertisements

Repair Difficulty

Very Easy 1/5

Required Part

Drip Tray
Check Price on Amazon

We may earn a commission from links on this page.