Monument Grills
Temperature Control Instability
Grill overshoots set temperature by more than 50°F and cycles wildly
Advertisements
Possible Causes
RTD probe coated in grease and soot, RTD probe positioned too close to heat source, Control board PID settings out of calibration, Air leaks around lid or door
How to Fix / Troubleshooting
Safety first: Let the grill cool before touching the RTD or seals.
- Step 1 – Clean RTD probe: Gently clean the Monument RTD probe inside the cook chamber with a soft cloth and degreaser to remove buildup.
- Step 2 – Check probe placement: Ensure the probe is mounted in its factory location and not bent toward the firepot or exhaust.
- Step 3 – Inspect lid seal: Check the lid gasket and body for gaps or warping that allow excess air in. Replace worn gaskets if equipped.
- Step 4 – Avoid frequent lid opening: Opening the lid repeatedly causes large swings. Allow the grill to stabilize after changes.
- Step 5 – Controller replacement: If temperature swings remain extreme after cleaning and sealing, the main control board may be mis‑controlling the auger and fan and should be replaced.