Nexgrill
No Power / Dead Control System
Pellet grill will not power on at all; no lights or display
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Tripped household breaker or GFCI, Faulty Nexgrill power cord, Loose internal power connections, Failed main control board power supply section
How to Fix / Troubleshooting
Safety first: Ensure the grill is switched OFF before plugging or unplugging.
- Check outlet: Test the wall outlet with another appliance. Reset any tripped GFCI or breaker.
- Inspect power cord: Look for cuts, burns, or crushed sections. Replace the Nexgrill power cord if damaged.
- Verify grill power switch: Some models have a rear or side rocker switch. Ensure it is in the ON position.
- Open control compartment: With the grill unplugged, remove the control panel or rear cover. Check that the power cord leads are firmly attached to the control board or terminal block.
- Look for board damage: If there is visible burning or a blown fuse on the board, the main control board likely needs replacement.
- Replace main control board if no low‑voltage output: If you have a meter and are qualified, check for low‑voltage output from the board. If absent, replace the board.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Main Control Board