ERR6
Oklahoma Joe’s
Low Voltage or Power Supply Fault
Controller displays ERR6 and grill will not power the fan or auger
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty AC power outlet, Damaged power cord, Failed internal power supply on control board, Loose neutral or ground connection
How to Fix / Troubleshooting
Safety first: Unplug the grill before removing any panels.
- Test the wall outlet with another appliance to confirm it has power and is not on a tripped GFCI or breaker.
- Inspect the grill’s power cord for cuts, crushed sections, or burn marks. Replace the cord if damaged.
- Remove the controller mounting screws and gently pull the control board out. Check for loose wire nuts, spade connectors, or burned components on the board.
- Ensure the main power input wires are tight on the control board terminals.
- If the display powers on but ERR6 persists and neither the fan nor auger run, the internal low‑voltage supply on the control board is likely failed. Replace the control board assembly with an OEM part.
Warning: Do not attempt board‑level repairs unless you are trained in electronics; replacing the entire board is the safe approach.