Er6
Pit Boss Internal Controller Fault / EEPROM Error

Display shows Er6 and grill will not operate normally.

Advertisements

Possible Causes

Corrupted controller firmware, Internal memory failure, Power surge damage, Moisture intrusion into control board

How to Fix / Troubleshooting

Safety first: Disconnect power before removing the controller.

  • Step 1 – Hard reset: Turn the dial to OFF. Unplug the grill for at least 5 minutes to fully discharge the controller. Plug back in and attempt to start on Smoke.
  • Step 2 – Inspect controller housing: Check for signs of water ingress, condensation, or grease inside the controller cavity. Dry thoroughly if moisture is present.
  • Step 3 – Check wiring harness: Ensure all connectors are firmly seated and no pins are bent or corroded.
  • Step 4 – Replace controller: If Er6 persists after reset and inspection, the main control board is likely defective and should be replaced with a Pit Boss–compatible replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Main Control Board
Check Price on Amazon