ER14
Rösle
Low-Temperature Control Fault / Incorrect Feed Rate
Display shows ER14; grill cannot reach low set temperatures and tends to run too hot at smoke settings.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect feed rate calibration in control board, Sticking auger causing uneven pellet delivery, Faulty low-speed control of auger motor, RTD probe placement error
How to Fix / Troubleshooting
Safety first: Unplug the grill before accessing internal components.
- Clean and inspect auger: Empty the hopper and check the auger for buildup or partial jams that could cause surging pellet feed. Clean as needed.
- Verify RTD position: Ensure the RTD probe is not too close to the firepot or heat diffuser, which can cause the controller to read higher than actual grate temperature.
- Controller calibration: Consult your Rösle manual for any available temperature offset or feed rate calibration settings. Adjust according to instructions.
- Test at low setpoint: Set the grill to a low smoke temperature and monitor with an independent grill thermometer. Note any large deviations.
- Replace control board if unresponsive: If ER14 persists and calibration has no effect, the control board's low-temperature control circuit may be faulty and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Main Control Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements