HI
Recteq Over-Temperature / Runaway Heat Condition

Display shows HI or temperature exceeds maximum reading; grill runs much hotter than setpoint.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

RTD probe reading too low due to placement or failure, Excessive pellet feed from controller or stuck auger relay, Grease fire adding uncontrolled heat

How to Fix / Troubleshooting

Immediate safety: If you suspect a grease fire, keep the lid closed, unplug the grill, and use a Class B fire extinguisher if flames escape. Do not use water.

Steps to address HI:

  • Allow cool-down: Leave the lid closed until the grill cools to a safe temperature. Do not open the lid during an active grease fire.
  • Inspect RTD probe: Once cool, check that the RTD is clean, not coated in thick carbon, and not bent into direct flame or touching metal surfaces. Clean gently with a non-abrasive pad.
  • Check for grease buildup: Remove grates and drip pan. Clean heavy grease from the drip tray, barrel bottom, and grease drain. Built-up grease can ignite and cause runaway temperatures.
  • Verify auger control: With the grill cool and empty, start a low-temp cook and observe pellet feed. If the auger runs continuously at low setpoints, the controller or auger relay may be stuck.
  • Test with empty cook chamber: Run the grill at a moderate setpoint (e.g., 250°F) with no food. Compare displayed temperature to an independent grill thermometer. Large discrepancies suggest RTD or controller calibration issues.
  • Replace RTD if needed: If the RTD is damaged or gives erratic readings, install a new Recteq-compatible RTD probe.

Warning: If the auger continues to feed uncontrollably or HI recurs after RTD replacement and cleaning, discontinue use and replace the controller. Uncontrolled heating is a fire hazard.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

RTD Temperature Probe
Check Price on Amazon