Royal Gourmet Auger Motor Electrical Failure

Auger motor is completely silent; no hum or movement when grill calls for pellets.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Burned-out auger motor on Royal Gourmet pellet feed, Disconnected auger motor plug, Failed auger relay on control board, Broken motor lead wire

How to Fix / Troubleshooting

Safety first: Disconnect power before testing the motor.

Steps to diagnose:

  • Check connector: Verify the auger motor plug is firmly connected to the control board.
  • Test motor directly: If you are qualified, bench-test the auger motor with the correct AC voltage to see if it runs. If it does not, the motor is faulty.
  • Measure voltage at board: During a feed cycle, measure AC voltage at the auger output terminals on the control board. If no voltage is present, the board or relay is faulty.
  • Replace failed part: Replace the auger motor if it fails bench testing, or replace the main control board if it does not supply power to a known-good motor.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Auger Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements