FAN
Tepro Combustion Fan Feedback / Failure

Display alternates FAN error and grill will not start or maintain fire

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Combustion fan motor seized, Fan blades obstructed by grease or debris, Disconnected fan wiring, Failed fan driver on control board

How to Fix / Troubleshooting

Safety first: Unplug the grill and ensure all components are cool.

  • 1. Access the fan: Remove the lower or rear service panel to expose the combustion fan assembly.
  • 2. Check for obstructions: Inspect the fan blades for grease buildup, foil, or debris. Clean thoroughly with a brush and degreaser, taking care not to bend the blades.
  • 3. Spin test: Rotate the fan by hand. It should spin freely without grinding. If it is stiff or seized, the motor must be replaced.
  • 4. Verify wiring: Ensure the fan connector is fully seated on the control board and that wires are not cut or burned.
  • 5. Power test: With the grill partially reassembled, plug it in and start a cook cycle. Listen and feel for fan operation. If the fan does not run but receives proper voltage (check with a multimeter), replace the fan motor. If no voltage is present, suspect the control board.
  • 6. Replace fan motor: Remove mounting screws, disconnect wiring, and install the new fan in the same orientation. Secure wiring away from moving parts and hot surfaces.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Combustion Fan Motor
Check Price on Amazon