ERR
Traeger General Controller Fault / Sensor Read Error

Controller displays “ERR” and grill will not start or respond to temperature changes.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose RTD temperature probe connection, Damaged RTD temperature probe, Faulty main control board, Corroded wiring harness connectors

How to Fix / Troubleshooting

Safety first: Unplug the grill from power before removing any panels. Allow the grill to cool completely.

  • 1. Power cycle the grill: Turn the power switch OFF, unplug for 5 minutes, then plug back in and turn ON. Check if the ERR clears.
  • 2. Inspect RTD temperature probe:
    • Locate the RTD probe inside the cook chamber (small metal rod on the side wall) and follow its wire to the controller.
    • Check for cuts, kinks, or burned insulation on the RTD wire.
    • At the controller, gently unplug and re-seat the RTD connector several times to clean the contacts.
  • 3. Check RTD resistance (if you have a multimeter):
    • Disconnect the RTD from the controller.
    • Measure resistance across the two RTD leads at room temperature (~70°F / 21°C). A typical Traeger RTD should read roughly 1000–2000 ohms (consult your model’s spec).
    • If the reading is open (OL), shorted (0 ohms), or far outside spec, replace the RTD temperature probe.
  • 4. Inspect controller and harness:
    • Remove the controller mounting screws and gently pull the controller out.
    • Check all harness plugs for corrosion, loose pins, or heat damage.
    • Firmly re-seat each connector one at a time.
  • 5. Replace failed component:
    • If a new RTD does not clear the ERR, the main control board is likely faulty and should be replaced as a complete controller assembly.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

RTD Temperature Probe
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements