Yoder Smokers Intermittent Power Loss

Grill powers on but shuts off randomly during cooks without an error code

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose power cord at inlet, Failing power switch contacts, Overheating controller, Vibration loosening internal connectors

How to Fix / Troubleshooting

Safety first: Unplug the grill before tightening or reseating any electrical connections.

  • Secure power cord: Ensure the cord is fully inserted into the grill's inlet and the wall outlet. Avoid tension on the cord.
  • Inspect power switch: Wiggle the switch gently while the grill is running (if safe to do so). If the display flickers, replace the power switch.
  • Check internal connectors: Remove the controller and verify all harness plugs are firmly seated. Apply dielectric grease if recommended.
  • Ventilation: Make sure the controller area is not blocked and can dissipate heat. Overheating can cause shutdowns.
  • Replace controller if needed: If all external causes are eliminated, an internal controller fault may be causing resets and the main control board should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements