Z Grills
No AC Power to Control Board
Grill will not power on; no lights or display on the Z Grills control panel.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty power outlet or tripped breaker, Damaged Z Grills power cord, Loose internal power connection at control board
How to Fix / Troubleshooting
Safety first: Before opening any panels, unplug the grill. Do not work on live AC circuits unless you are qualified.
Steps to troubleshoot:
- Check outlet and breaker: Test the outlet with another device. Reset any tripped breakers or GFCI outlets.
- Inspect power cord: Examine the entire length of the Z Grills power cord for cuts, burns, or crushed sections. Replace if damaged.
- Verify grill switch (if equipped): Some models have a rocker switch in addition to the control knob. Ensure it is in the ON position.
- Inspect internal connections: Remove the control panel and confirm the main AC input wires are firmly attached to the control board terminals and any inline connectors.
- Fuse check: Look for an inline or board-mounted fuse near the AC input. With power disconnected, remove and inspect the fuse. Replace with the same rating if blown.
- Replace control board if dead: If power is present at the board input but there are no lights or display, replace the control board.
Advertisements
Repair Difficulty
Medium
3/5