PF
AquaCal
Power Interruption / Low Voltage Fault
Display shows PF or POWER FAIL; unit may reset unexpectedly or lose settings.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose power lugs at contactor or terminal block, Undersized supply wiring causing voltage drop, Faulty circuit breaker or disconnect, Intermittent power relay on control board
How to Fix / Troubleshooting
Safety first: Turn off power at the main breaker and lock it out if possible. Use a multimeter only if you are trained and comfortable working with high voltage.
- Inspect power connections: Remove the electrical access cover on the AquaCal unit. Check that all line and load wires are tight on the terminal block and contactor.
- Check for overheating: Look for discoloration, melted insulation, or burnt smells around terminals, which indicate poor connections.
- Verify breaker size: Confirm the circuit breaker and wire gauge match AquaCal's installation specifications for your model.
- Test voltage: With power restored and using proper PPE, measure line voltage at the unit while the heater is running. If voltage is significantly below nameplate rating, consult an electrician.
- Control board/relay: If supply power is stable but PF persists, the internal power relay or control board may be failing and should be replaced by an AquaCal service technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Contactor / Power Terminal Block