AquaCal
Compressor Start Failure
Fan runs but compressor does not start; no heating occurs.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed compressor start/run capacitor, Faulty compressor contactor, Open compressor winding, Internal compressor mechanical failure
How to Fix / Troubleshooting
Safety first: High voltage and stored energy in capacitors can be dangerous. Discharge capacitors properly before handling.
- Listen for compressor: If there is no hum or click when heat is demanded, suspect the contactor or control board.
- Inspect contactor: Check for burnt or pitted contacts and verify the coil is being energized. Replace if defective.
- Test capacitor: Use a capacitance meter to verify the compressor capacitor value. Replace if out of tolerance.
- Compressor test: A technician should check compressor winding resistance and megger insulation. Replace the compressor if windings are open or shorted.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Compressor Start/Run Capacitor
Check Price on Amazon
We may earn a commission from links on this page.