F3
AstralPool
Ignition Lockout (Retries Exceeded)
Heater shows F3; fan may run but ignition does not occur.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Weak spark from ignition electrode, Dirty flame sensor, Low gas pressure, Faulty gas valve coil
How to Fix / Troubleshooting
Safety first: Turn off gas and power. Do not repeatedly reset a heater that fails to ignite; unburned gas can accumulate.
- Inspect ignition electrode and flame sensor: Clean both rods with fine emery cloth and ensure correct gap and positioning per AstralPool specifications.
- Check ground connections: Ensure the burner tray and ignition module have solid ground connections to the chassis; poor grounding can weaken spark and flame sensing.
- Verify gas supply: Confirm gas valves are open and that other gas appliances function normally.
If F3 persists, a technician should test the gas valve, ignition module, and measure gas pressure during ignition.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
AstralPool Gas Valve
Check Price on Amazon