F3
AstralPool Ignition Lockout (Retries Exceeded)

Heater shows F3; fan may run but ignition does not occur.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Weak spark from ignition electrode, Dirty flame sensor, Low gas pressure, Faulty gas valve coil

How to Fix / Troubleshooting

Safety first: Turn off gas and power. Do not repeatedly reset a heater that fails to ignite; unburned gas can accumulate.

  • Inspect ignition electrode and flame sensor: Clean both rods with fine emery cloth and ensure correct gap and positioning per AstralPool specifications.
  • Check ground connections: Ensure the burner tray and ignition module have solid ground connections to the chassis; poor grounding can weaken spark and flame sensing.
  • Verify gas supply: Confirm gas valves are open and that other gas appliances function normally.

If F3 persists, a technician should test the gas valve, ignition module, and measure gas pressure during ignition.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

AstralPool Gas Valve
Check Price on Amazon

We may earn a commission from links on this page.