F9
AstralPool Power Supply / Line Voltage Fault

Heater shows F9; may occur after incorrect wiring or polarity issues.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect supply voltage, Reversed polarity or missing neutral, Loose power connections, Internal power supply failure on PCB

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker. Only qualified persons should work on mains wiring.

  • Verify supply voltage: Confirm that the heater is connected to the correct voltage (e.g., 230 V single-phase) as specified on the AstralPool rating plate.
  • Check terminal block: Inspect the incoming power terminals for loose screws, discoloration, or burnt insulation. Tighten as needed.
  • Confirm polarity and earth: Ensure active, neutral, and earth are correctly connected according to the wiring diagram.

If wiring is correct and F9 remains, the internal power supply on the main board may be damaged and require board replacement.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

AstralPool Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements