AstralPool No Ignition Command / Control Logic Issue

Heater fan runs but there is no ignition sound or flame, and no error code is displayed.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Thermostat not calling for heat, Faulty water temperature sensor reading above setpoint, Stuck relay on control board, External controller not enabling heater

How to Fix / Troubleshooting

Safety first: Turn off power before accessing control wiring.

  • Confirm call for heat: Ensure the set temperature is higher than the actual water temperature and that the correct mode (pool/spa) is selected.
  • Check external controls: If using automation, verify that the heater is enabled in the controller and that the heater input is being closed when heat is requested.
  • Observe temperature reading: If the displayed water temperature is much higher than actual, the sensor may be faulty and preventing ignition.

If the fan runs continuously without ignition, the control board may require diagnosis and possible replacement.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

AstralPool Main Control Board
Check Price on Amazon