E4
Certikin Flow Rate Below Minimum / Differential Temperature Too High

E4 error; heater may start but then shuts down quickly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Undersized circulation pump for Certikin heater, Partially closed valves, Blocked heater inlet strainer, Internal fouling of heat exchanger reducing flow

How to Fix / Troubleshooting

Safety first: Turn off power to the heater and pump before opening any pipework or strainers.

  • Confirm pump size and speed: Ensure the circulation pump is correctly sized and, if variable speed, set to a speed that meets the heater’s minimum flow requirement.
  • Open valves fully: Check all isolation and bypass valves around the heater and set them to provide maximum flow through the heater.
  • Clean inlet strainers: Some Certikin heaters have an inlet strainer or filter; remove and clean any debris.
  • Backwash filter: Perform a full backwash and rinse on the pool filter to reduce system resistance.
  • Restart and monitor: Restore power and observe the heater. If E4 persists, internal scaling may be present.

Severe internal fouling of the heat exchanger requires chemical cleaning or replacement by a professional.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Certikin heat exchanger / circulation pump
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements