F8
Certikin Control PCB Communication / Internal Fault

Heater shows F8 and will not start; may occur after a power surge or wiring work.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Internal failure of Certikin main control PCB, Loose low-voltage harness connections, Incorrect supply voltage or polarity, Damage from electrical surge or moisture ingress

How to Fix / Troubleshooting

Safety first: Turn off power at the isolator and verify with a tester before touching internal components.

  • Inspect control compartment: Remove the front panel and check for signs of water ingress, condensation, or insect infestation around the PCB.
  • Check all plugs: Gently press all multi-pin connectors and terminal blocks on the control board to ensure they are fully seated.
  • Verify supply voltage: Confirm that the heater is supplied with the correct voltage (e.g. 230 V single phase) and that neutral and earth connections are secure.
  • Look for burn marks: If there are obvious burn marks or swollen components on the PCB, do not attempt repair.
  • Power cycle: Leave the unit powered off for several minutes, then restore power and check if F8 clears.

Persistent F8 errors typically require replacement of the Certikin control PCB and should be handled by an authorised service agent.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Certikin main control PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements