E03
Elecro Water Temperature Sensor (NTC) Fault

Display shows E03 and heater will not energize elements.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed Elecro NTC temperature probe, Broken or shorted sensor cable, Corroded sensor connector on control PCB, Sensor not fully immersed in water stream

How to Fix / Troubleshooting

Safety first: Isolate electrical power before removing covers or touching wiring.

  • Visual inspection: Locate the Elecro water temperature sensor (NTC probe) on the heater manifold or in the flow tube. Check that it is fully inserted and secured.
  • Check cable and plug: Follow the sensor cable to the control PCB. Look for cuts, abrasions, or rodent damage. Ensure the connector is firmly seated and free of corrosion.
  • Basic resistance test (for competent users): With power off and sensor disconnected, measure resistance across the NTC sensor with a multimeter. Compare to Elecro’s temperature/resistance chart. An open circuit or zero ohms indicates a failed sensor.
  • Clean contacts: If mild corrosion is present on the plug, clean with electrical contact cleaner and reconnect.

If the sensor is out of specification or physically damaged, replace it with the correct Elecro NTC temperature sensor for your model.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Elecro Water Temperature Sensor (NTC Probe)
Check Price on Amazon