E11
Elecro Calibration / Temperature Offset Error

Display shows E11; heater may run but not reach set temperature or may shut down prematurely.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Mis-calibrated Elecro thermostat, Faulty temperature sensor reading offset, Incorrect parameter settings in control PCB, Sensor not properly seated in flow tube

How to Fix / Troubleshooting

Safety first: Isolate power before adjusting internal controls.

  • Compare temperatures: Use a reliable pool thermometer to compare actual water temperature with the heater display. Note any consistent offset.
  • Check sensor seating: Ensure the NTC sensor is fully inserted into its pocket or flow tube and secured with the retaining clip.
  • Access calibration menu: If your Elecro model supports it, enter the installer menu (refer to manual) and adjust the temperature offset to match actual water temperature.
  • Inspect sensor cable: Look for partial breaks or moisture that could cause drift in readings.

If calibration cannot correct the error or readings are unstable, replace the Elecro temperature sensor and, if needed, the control PCB.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Elecro Water Temperature Sensor (NTC) / Digital Thermostat
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements