Elecro Sensor Drift / Aging NTC

Heater’s temperature reading drifts slowly over time, becoming inaccurate by several degrees.

Advertisements

Possible Causes

Aging Elecro NTC sensor, Long sensor cable run picking up interference, Poor electrical connection at PCB, Operation at high temperatures accelerating sensor wear

How to Fix / Troubleshooting

Safety first: Isolate power before handling sensors or PCB connections.

  • Compare with reference: Periodically compare the heater’s displayed temperature with a calibrated pool thermometer.
  • Inspect connections: Reseat the sensor connector on the PCB and check for corrosion.
  • Replace sensor: If drift exceeds a few degrees and cannot be calibrated out, replace the Elecro NTC sensor with a new one.

Regular calibration checks help maintain accurate temperature control.