bYP
Fafco Forced Bypass / Service Mode

Display shows bYP or BYPASS ONLY; system refuses to send water to solar panels.

Advertisements

Possible Causes

Controller set to SERVICE or BYPASS mode, Roof sensor reading too cold for solar, Freeze protection mode active, Manual override switch on Fafco controller engaged

How to Fix / Troubleshooting

Safety: No plumbing work is required for this check, but always be cautious around live electrical equipment.

  • Check mode setting: On the Fafco controller front panel, verify the mode is set to AUTO or HEAT, not SERVICE or BYPASS. Change to AUTO and observe operation.
  • Inspect manual override: Some Fafco controllers have a physical toggle or dip switch for bypass. Ensure it is in the normal operating position.
  • Review temperature conditions: If the roof sensor is colder than the pool or near freezing, the controller will intentionally bypass. Confirm actual temperatures and wait for warmer conditions.
  • Freeze protection: If freeze protection is enabled, the system may run in bypass to protect plumbing. Verify freeze settings in the controller menu.
  • Power-cycle: Turn the controller off for 30 seconds and back on to clear any latched bypass state, then test again.
Advertisements

Repair Difficulty

Very Easy 1/5