E02
Fairland High Refrigerant Pressure Protection

Pool heater stops heating and displays E02; fan may run briefly then stop.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty or blocked condenser/evaporator coil, Faulty condenser fan motor, Overcharged refrigerant, Blocked water flow through titanium heat exchanger causing poor heat transfer

How to Fix / Troubleshooting

Safety: Switch off power at the breaker before touching the unit. Do not attempt to vent or adjust refrigerant yourself.

Steps to try:

  • Check water flow: Confirm the pool pump is on and the filter is clean. Backwash or clean cartridges. Ensure bypass valves around the Fairland heater are correctly set so adequate flow passes through the titanium heat exchanger.
  • Clean the coil: Inspect the large finned coil on the Fairland unit. Remove debris and gently wash with a garden hose (no high pressure). Straighten any badly bent fins with a fin comb.
  • Verify fan operation: With power restored, start the unit and observe from a safe distance. The top or side fan (depending on model) should start when the compressor runs. If the fan does not run or is very slow, shut power off and call a technician.

Technician tasks:

  • Test and replace the condenser fan motor or capacitor if defective.
  • Check for overcharge or non-condensables in the refrigerant circuit and correct as needed.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Condenser Fan Motor
Check Price on Amazon