E03
Fairland
Water Flow Protection / Low Water Flow
Unit attempts to start but quickly shuts down with E03 on the display.
Advertisements
Possible Causes
Clogged pool filter, Closed isolation valve on heater inlet or outlet, Faulty flow switch in Fairland water circuit, Air lock in plumbing to heater
How to Fix / Troubleshooting
Safety: Turn off the heater before working on pool plumbing. Do not run the heater without proper water flow.
What to check:
- Pool pump and filter: Ensure the circulation pump is running. Clean or backwash the filter. Check pump basket and skimmer baskets for debris.
- Valves: Confirm that the inlet and outlet valves to the Fairland heater are fully open. If a bypass is installed, adjust it so that sufficient flow passes through the heater.
- Air in system: If plumbing was recently serviced, bleed air from high points or open a return line briefly to purge air.
- Flow switch: Locate the Fairland flow switch on the water inlet line (usually a small tee with wires). Inspect for kinks or damage to the cable.
If E03 persists:
- A technician should test and, if necessary, replace the water flow switch and verify correct plumbing configuration and flow rate.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Water Flow Switch