E16
Fairland Current Sensor / Overcurrent Detection Fault

Display shows E16; heater may run at reduced capacity or shut down.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective current transformer (CT) on compressor line, Loose CT connector on PCB, Shorted wiring causing false overcurrent reading, Faulty main PCB analog input

How to Fix / Troubleshooting

Safety: High voltage present. Only open the electrical compartment with power off and if you are competent to do so.

Checks:

  • Visual inspection: Locate the current sensor (CT) around the compressor supply wire. Ensure it is intact and its plug is firmly seated on the PCB.
  • Look for overheating: Check for discolored wires or melted insulation that might indicate real overcurrent.

Resolution:

  • If no wiring damage is found, a technician should test and replace the current sensor or main PCB as needed.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Current Sensor (CT) on Compressor Circuit
Check Price on Amazon