Possible Causes

Faulty compressor contactor, Failed start/run capacitor (non-inverter models), Loose compressor wiring, Internal compressor failure

How to Fix / Troubleshooting

Safety: High voltage and stored energy in capacitors are present. Only open the electrical compartment if you are qualified.

User observations:

  • Listen for compressor: With the unit running, listen for the deeper hum of the compressor. If only the fan noise is present, the compressor is not starting.

Technician actions:

  • Test the compressor contactor coil and contacts.
  • Check and replace the start/run capacitor if out of specification.
  • Measure compressor winding resistance and insulation.