ROL
Hayward
Flame Rollout Safety Trip
Heater displays ROL or rollout error; unit locks out and will not fire.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked burner orifices, Blocked heat exchanger or flue, Soot buildup, Failed rollout switch
How to Fix / Troubleshooting
Safety First: Turn off power and gas immediately. A rollout condition is a serious safety issue. Do not repeatedly reset and operate the heater until the cause is corrected.
- Inspect rollout switch: Locate the rollout switch near the burner area. If it has a manual reset button, press it once after the unit has cooled. If it trips again, stop and investigate further.
- Check for soot and blockage: Look for black soot around the burners or flue outlet, indicating poor combustion or blockage. Do not operate the heater if soot is present.
- Examine burner area: Ensure no debris, spider webs, or rust flakes are blocking burner ports.
- Professional service: Flame rollout often indicates serious combustion or venting problems. Contact a qualified technician to clean the heat exchanger, verify combustion, and replace any damaged rollout switches.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Flame Rollout Switch
Check Price on Amazon
We may earn a commission from links on this page.