d1
Heat Siphon Defrost Sensor / Circuit Error

Display shows “d1” and unit will not start heating.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted defrost sensor, Incorrect sensor placement, Faulty control board defrost circuit

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing sensors.

  • Locate defrost sensor: Usually attached to the evaporator coil or refrigerant line leaving the coil.
  • Inspect and reseat: Ensure the sensor is securely clipped and making good thermal contact. Reseat the connector at the control board.
  • Measure resistance: Compare to the Heat Siphon spec chart. Replace if readings are abnormal.
  • Board evaluation: If a new sensor does not clear d1, the control board may need replacement by a qualified technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Defrost Sensor
Check Price on Amazon