VAL
Heliocol Solar Diverter Valve Actuator Fault

Controller displays VAL or VALVE and the solar valve does not move when solar heat is requested.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed 24V valve actuator motor, Stripped actuator gears, Misaligned actuator cams, Loose or broken actuator wiring harness

How to Fix / Troubleshooting

Safety first: Turn off power to the controller and pump before working on the valve actuator. Do not manually force the valve while powered.

  • Check actuator power: With power on and a call for solar, use a multimeter at the actuator leads to confirm the controller is sending the correct voltage (typically 24 VAC). If no voltage is present, suspect the controller or wiring.
  • Inspect wiring: Turn power off, open the actuator cover, and check for loose or corroded wire nuts or terminal screws. Repair or replace damaged wiring.
  • Test manual operation: Use the manual override lever on the valve body to ensure the Jandy-style diverter valve itself turns freely. If it is stiff or seized, the valve body may need service.
  • Check cam settings: Verify the internal stop cams are set to allow full travel between pool and solar positions. Adjust cams according to the actuator manual.
  • Replace actuator if necessary: If the motor hums but does not move, or if gears are stripped, replace the actuator with a compatible Heliocol-approved solar valve actuator.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Solar Valve Actuator