Improper Controller Configuration or Setpoint Settings
Solar heating never turns on even when pool is below setpoint and roof is hot; no error codes displayed.
Advertisements
Possible Causes
Solar mode disabled in controller, Pool temperature setpoint too low, Differential temperature setting too high, Time-of-day restrictions enabled
How to Fix / Troubleshooting
Safety first: Follow controller manual when changing settings. No need to power off for normal menu adjustments.
- Check operating mode: Ensure the controller is set to automatic solar mode and not manual off or service mode.
- Verify setpoint: Confirm the desired pool temperature is set above the current pool temperature.
- Adjust differential: Set the solar-on temperature differential (difference between roof and pool) to a reasonable value (often 4–8°F) so the system will activate.
- Review timers: Disable any time-of-day lockouts that might be preventing solar operation during sunny hours.
Advertisements
Repair Difficulty
Very Easy
1/5
Required Part
Solar Controller
Check Price on Amazon